Notes for deployment of MD OT Security | Firewall Allow-listed Configurations
This document outlines the URLs and ports that must be allowed in the firewall to ensure proper functionality of the Network Sensor, Site Manager, and Enterprise Manager.
Allow-listed URLs
The following URLs are required for system operations and updates:
- https://my.opswat.com: Access to the OPSWAT business support portal.
- https://activation.dl.opswat.com: License activation and validation.
- https://mdots-cdn.opswat.com: Content delivery for updates and resources.
Allow-listed Ports
The following ports must be open for communication between components
Network Sensor
1443:
- Purpose: Using for communication from Site Manager to Network Sensor.
- Only required when communication between Site Manager and Network Sensor is Bi-Directional. (ie: no need if communication between Site Manager and Network Sensor is Uni-Directional.)
- Communication is secured by TLS 1.3.
- Authentication is token-based.
- Token lifecycle:
- Version < 3.5.0: Token never expires until next established connection.
- From version 3.5.0: Token will expire according to configuration.
443:
- Purpose: Using for user to perform initial configuration via web console.
- Communication is secured by TLS 1.3.
- Authentication: User account credentials.
Site Manager
3006:
- Purpose: For the communication between Site Manager with Network Sensor and Enterprise Manager.
- From Network Sensor to Site Manager (Uni-Directional and Bi-Directional)
- From Enterprise Manager to Site Manager (Bi-Directional)
- Purpose: For the communication between Site Manager with Network Sensor and Enterprise Manager.
5672:
- Purpose: Using for sending and receiving message queue service between Site Manager with Network Sensor and Enterprise Manager.
- Receiving and sending message from Network Sensor to Site Manager (Uni-Directional and Bi-Directional)
- Receiving message from Enterprise Manager to Site Manager (Bi-Directional)
- Purpose: Using for sending and receiving message queue service between Site Manager with Network Sensor and Enterprise Manager.
443:
- Purpose: Using for user to perform initial configuration via web console.
- Communication is secured by TLS 1.3.
- Authentication: User account credentials.
Enterprise Manager
443:
- Purpose: For user to work with MD OT Security Enterprise via web console.
- Communication is secured by TLS 1.3.
- Authentication: User account credentials.
3003:
- Purpose:
- For user to work with MD OT Security Enterprise via web console.
- For the communication between from Enterprise Manager to Site Manager. (Uni-Directional and Bi-Directional)
- Purpose:
5673:
- Purpose: Using for receiving message queue service from Site Manager (Uni-Directional and Bi-Directional)
Summary of open Ports on MD OT Security components for inbound connections
Purpose/ Usage | Network Sensor | Site Manager | Enterprise Manager |
---|---|---|---|
For users to use/ interact with the component via web console | 443 (main use-case: initial configurations) | 443 (main use-case: initial configurations) | 443 (User’s daily use of MD OT Security via Enterprise Management Console) |
For the lower component to communicate with the component | N/A (There is no MDOTS component under the sensor component) | 3006, 5672 (for Sensors to communicate with Site Manager) | 3003, 5673 (for Site Managers to communicate with Enterprise Manager) |
For the upper component to communicate with the component (only applicable if the communication between the two components is set to Bi-directional) | 1443 (For Site Manager to communicate with Sensor) | 3006, 5672 (for Enterprise Manager to communicate with Site Manager) | N/A (There is no MDOTS component above Enterprise Manager) |
For SSH Access | 22 | 22 | 22 |
Summary of open Ports for outbound connections from MD OT Security components
Purpose/ Usage | Connection from Network Sensor | Connection from Site Manager | Connection from Enterprise Manager |
---|---|---|---|
LDAP Authentication (For communicating with LDAP Server) | 636 (secure) 389 (insecure) | ||
Integration with NAC (For communicating with ClearPass Policy Manager Server) | 443 | ||
For Smart Asset Profiling | 80: HTTP for ABB profile 47808: UDP for BACnet/IP profile 80: HTTP for B&R Industrial Automation profile 18245: UDP for Emerson (GE-SRTP) profile 80: HTTP for Emerson (HTTP) profile 44818: TCP for EtherNet/IP profile 5562: TCP Mitsubishi profile 502: TCP for Modbus-TCP profile 34964: UDP for PROFINET IO (DCE/RPC) profile 102: TCP for S7COMM-PLUS profile - Extended 102: TCP for S7COMM profile 161: UDP for SNMP profile |
Notes
- Ensure that traffic is allowed for the listed URLs and ports.
- Verify that no intermediate proxies or firewalls block these connections.
- Contact the system administrator or OPSWAT support if additional configuration is required.
Was this page helpful?
On This Page
Notes for deployment of MD OT Security | Firewall Allow-listed ConfigurationsThis document outlines the URLs and ports that must be allowed in the firewall to ensure proper functionality of the Network Sensor, Site Manager, and Enterprise Manager.Allow-listed URLsAllow-listed PortsNetwork SensorSite ManagerEnterprise ManagerSummary of open Ports on MD OT Security components for inbound connectionsSummary of open Ports for outbound connections from MD OT Security componentsNotes